PIPING / Pipe Pressure Drop Calculator

Pipe Pressure Drop Calculator

Calculate Darcy–Weisbach friction pressure drop, minor losses and elevation change from bore, length, flow and fluid properties, with Reynolds number and friction factor.

Inputs

Updates as you type

kg/m³

mPa·s = cP

Results

Total pressure drop

26.228kPa
Results
Total pressure drop0.262 bar
Total pressure drop3.804 psi
Friction pressure drop26.228 kPa
Friction drop per 100 m26.228 kPa/100 m
Head loss2.679 m
Velocity1.691 m/s
Reynolds number · Re172,343.569
Flow regimeTurbulent · Re ≥ 4,000
Darcy friction factor · f0.019
Relative roughness · ε/D4.401e-4

Overview

Calculate the friction pressure drop of a liquid flowing in a pipe with the Darcy–Weisbach equation. Enter the bore, length, flow, fluid density and viscosity and the pipe roughness to get the Reynolds number and friction factor, then the pressure drop (kPa, bar, psi), the drop per 100 m and the head loss. You can add the sum of valve and fitting loss coefficients (ΣK) and an elevation change, which makes it a starting point for pump head checks and line sizing.

Formula

v = Q / (πD²/4)
Re = ρvD / μ
Laminar (Re < 2,300): f = 64 / Re
Turbulent: 1/√f = −2 log10(ε/(3.7D) + 2.51/(Re√f))  (Colebrook–White)
ΔPf = f × (L/D) × ρv²/2
ΔPm = ΣK × ρv²/2,  ΔPz = ρgΔz
ΔP = ΔPf + ΔPm + ΔPz,  hL = (ΔPf + ΔPm) / (ρg)

Example

Sending 50 m³/h of 20 °C water (998.2 kg/m³, 1.0016 mPa·s) through 100 m of NPS 4 Sch 40 (102.26 mm bore) gives 1.691 m/s, a Reynolds number of about 172,000 (turbulent) and a friction factor of about 0.0188, so the friction pressure drop is about 26.23 kPa (0.262 bar), or about 2.68 m of head. Adding valves and elbows with ΣK = 5 and a 10 m rise adds about 7.14 kPa of minor losses and about 97.89 kPa of elevation, for about 131.25 kPa (1.313 bar) in total. The elevation term can easily outweigh friction.

How to use

  1. Enter the pipe bore (not the outside diameter), length and flow with their units. The bore of standard pipe is in the pipe schedule chart.
  2. Enter the fluid density (kg/m³), dynamic viscosity (mPa·s = cP) and pipe roughness (mm). If needed, add the sum of valve and fitting loss coefficients ΣK and the end-minus-start elevation change.
  3. Read the total pressure drop with its friction, minor and elevation parts and the drop per 100 m, and use the Reynolds number and flow regime to check that the conditions fit.

Engineering notes

  • The calculation assumes a fluid of nearly constant density, such as a liquid, filling a round pipe. Gas lines whose pressure drop exceeds about 10% of the inlet pressure need a separate calculation that accounts for compressibility.
  • The default roughness of 0.045 mm is a common value for new commercial steel pipe. Old, corroded or scaled pipe is rougher, and stainless or plastic pipe smoother; use the value from the specification or design basis.
  • Reynolds numbers of 2,300–4,000 are the transition between laminar and turbulent flow. There the turbulent (Colebrook–White) equation is applied, which errs on the high side, and the result is uncertain.
  • Water density and viscosity change with temperature: about 998.2 kg/m³ and 1.0016 mPa·s at 20 °C, and about 983.2 kg/m³ and 0.467 mPa·s at 60 °C, less than half the viscosity.
  • Loss coefficients K depend on valve type and opening, fitting geometry and manufacturer. This tool uses only the ΣK entered, so add up the K values from your reference data.
  • Enter the elevation change as positive when the end is higher; that much more static pressure is needed. Downhill it is negative and can reduce the total drop or make it negative.

Frequently asked questions FAQ

What pressure drop per 100 m is reasonable?

It depends on the service and project criteria, and this tool does not judge an allowable value. Compare the drop per 100 m and the velocity for each candidate size at the same flow, and balance pump power against piping cost according to the applicable criteria.

Why does changing roughness not change a laminar result?

Below a Reynolds number of 2,300 the friction factor is f = 64/Re, independent of roughness. For example, oil at 870 kg/m³ and 100 mPa·s flowing at 5 m³/h in a 52.51 mm bore has Re ≈ 293 and loses about 74.43 kPa per 100 m whether the roughness is 0.045 mm or 0.5 mm.

How do head loss (m) and pressure drop (kPa) convert?

hL = ΔP / (ρg). For 20 °C water one meter of head is about 9.79 kPa, so 26.23 kPa is about 2.68 m. Head is the convenient form when comparing with pump head.

If the flow doubles, how much does the pressure drop rise?

In turbulent flow it rises roughly with the square of velocity, but the friction factor falls slightly as the Reynolds number grows, so a little under 4 times: in the example pipe, going from 50 to 100 m³/h multiplies the drop by about 3.76. In laminar flow it is proportional to flow.

Related guides

KEEP WORKING

Find the bore of standard pipe in the pipe schedule chart, and use the pipe flow velocity calculator for a quick velocity check. Use the pressure converter to bring the result into bar, psi, kgf/cm² or other units.