Pipe Pressure Drop Calculator
Calculate Darcy–Weisbach friction pressure drop, minor losses and elevation change from bore, length, flow and fluid properties, with Reynolds number and friction factor.
Inputs
Updates as you typekg/m³
mPa·s = cP
Results
Total pressure drop
| Total pressure drop | 0.262 bar |
|---|---|
| Total pressure drop | 3.804 psi |
| Friction pressure drop | 26.228 kPa |
| Friction drop per 100 m | 26.228 kPa/100 m |
| Head loss | 2.679 m |
| Velocity | 1.691 m/s |
| Reynolds number · Re | 172,343.569 |
| Flow regime | Turbulent · Re ≥ 4,000 |
| Darcy friction factor · f | 0.019 |
| Relative roughness · ε/D | 4.401e-4 |
Overview
Calculate the friction pressure drop of a liquid flowing in a pipe with the Darcy–Weisbach equation. Enter the bore, length, flow, fluid density and viscosity and the pipe roughness to get the Reynolds number and friction factor, then the pressure drop (kPa, bar, psi), the drop per 100 m and the head loss. You can add the sum of valve and fitting loss coefficients (ΣK) and an elevation change, which makes it a starting point for pump head checks and line sizing.
Formula
v = Q / (πD²/4) Re = ρvD / μ Laminar (Re < 2,300): f = 64 / Re Turbulent: 1/√f = −2 log10(ε/(3.7D) + 2.51/(Re√f)) (Colebrook–White) ΔPf = f × (L/D) × ρv²/2 ΔPm = ΣK × ρv²/2, ΔPz = ρgΔz ΔP = ΔPf + ΔPm + ΔPz, hL = (ΔPf + ΔPm) / (ρg)
Example
How to use
- Enter the pipe bore (not the outside diameter), length and flow with their units. The bore of standard pipe is in the pipe schedule chart.
- Enter the fluid density (kg/m³), dynamic viscosity (mPa·s = cP) and pipe roughness (mm). If needed, add the sum of valve and fitting loss coefficients ΣK and the end-minus-start elevation change.
- Read the total pressure drop with its friction, minor and elevation parts and the drop per 100 m, and use the Reynolds number and flow regime to check that the conditions fit.
Engineering notes
- The calculation assumes a fluid of nearly constant density, such as a liquid, filling a round pipe. Gas lines whose pressure drop exceeds about 10% of the inlet pressure need a separate calculation that accounts for compressibility.
- The default roughness of 0.045 mm is a common value for new commercial steel pipe. Old, corroded or scaled pipe is rougher, and stainless or plastic pipe smoother; use the value from the specification or design basis.
- Reynolds numbers of 2,300–4,000 are the transition between laminar and turbulent flow. There the turbulent (Colebrook–White) equation is applied, which errs on the high side, and the result is uncertain.
- Water density and viscosity change with temperature: about 998.2 kg/m³ and 1.0016 mPa·s at 20 °C, and about 983.2 kg/m³ and 0.467 mPa·s at 60 °C, less than half the viscosity.
- Loss coefficients K depend on valve type and opening, fitting geometry and manufacturer. This tool uses only the ΣK entered, so add up the K values from your reference data.
- Enter the elevation change as positive when the end is higher; that much more static pressure is needed. Downhill it is negative and can reduce the total drop or make it negative.
Frequently asked questions FAQ
What pressure drop per 100 m is reasonable?
It depends on the service and project criteria, and this tool does not judge an allowable value. Compare the drop per 100 m and the velocity for each candidate size at the same flow, and balance pump power against piping cost according to the applicable criteria.
Why does changing roughness not change a laminar result?
Below a Reynolds number of 2,300 the friction factor is f = 64/Re, independent of roughness. For example, oil at 870 kg/m³ and 100 mPa·s flowing at 5 m³/h in a 52.51 mm bore has Re ≈ 293 and loses about 74.43 kPa per 100 m whether the roughness is 0.045 mm or 0.5 mm.
How do head loss (m) and pressure drop (kPa) convert?
hL = ΔP / (ρg). For 20 °C water one meter of head is about 9.79 kPa, so 26.23 kPa is about 2.68 m. Head is the convenient form when comparing with pump head.
If the flow doubles, how much does the pressure drop rise?
In turbulent flow it rises roughly with the square of velocity, but the friction factor falls slightly as the Reynolds number grows, so a little under 4 times: in the example pipe, going from 50 to 100 m³/h multiplies the drop by about 3.76. In laminar flow it is proportional to flow.
Related guides
Related tools
Find the bore of standard pipe in the pipe schedule chart, and use the pipe flow velocity calculator for a quick velocity check. Use the pressure converter to bring the result into bar, psi, kgf/cm² or other units.
Pipe Flow Velocity Calculator
Calculate average full-bore velocity from inside diameter and volumetric flow, with results in m/s and ft/s.
Open calculatorPipe Schedule Chart (NPS)
Pipe Schedule Chart
Look up outside diameter, wall thickness, bore and weight per meter of steel pipe by NPS and schedule (Sch 5S–160, STD, XS, XXS), and compare schedules.
Open calculatorPressure Converter
Convert one pressure value simultaneously to Pa, kPa, MPa, bar, kgf/cm² and psi.
Open calculator