PIPING / JIS B 2220 Flange Chart

JIS B 2220 Flange Chart

Look up outside diameter, thickness, bolt circle (PCD), bolt count and thread size and bolt hole diameter of JIS B 2220 5K, 10K, 16K and 20K steel pipe flanges by nominal size (A).

Inputs

Updates as you type

Results

Flange outside diameter

210mm
Results
Flange thickness · t18 mm
Bolt circle · PCD175 mm
Number of bolts8
Bolt sizeM16
Bolt hole diameter19 mm
Matching pipe outside diameter114.3 mm

JIS B 2220 10K flange dimensions

Nominal size · AFlange outside diameter · mmFlange thickness · t · mmBolt circle · PCD · mmNumber of boltsBolt hole diameter · mmMatching pipe outside diameter · mm
10A · 3/8B9012654 × M121517.3
15A · 1/2B9512704 × M121521.7
20A · 3/4B10014754 × M121527.2
25A · 1B12514904 × M161934.0
32A · 1-1/4B135161004 × M161942.7
40A · 1-1/2B140161054 × M161948.6
50A · 2B155161204 × M161960.5
65A · 2-1/2B175181404 × M161976.3
80A · 3B185181508 × M161989.1
90A · 3-1/2B195181608 × M1619101.6
100A · 4B210181758 × M1619114.3
125A · 5B250202108 × M2023139.8
150A · 6B280222408 × M2023165.2
175A · 7B3052226512 × M2023190.7
200A · 8B3302229012 × M2023216.3
225A · 9B3502231012 × M2023241.8
250A · 10B4002435512 × M2225267.4
300A · 12B4452440016 × M2225318.5
350A · 14B4902644516 × M2225355.6
400A · 16B5602851016 × M2427406.4
450A · 18B6203056520 × M2427457.2
500A · 20B6753062020 × M2427508.0
600A · 24B7953273024 × M3033609.6

Overview

A chart of JIS B 2220 steel pipe flanges in 5K, 10K, 16K and 20K: outside diameter (D), thickness (t), bolt circle diameter (PCD, C), number and thread size of the bolts and bolt hole diameter (h) for each nominal size in A. It also shows the outside diameter of the pipe the flange fits. The table under the results compares every size of the same nominal pressure, for checking piping drawings, preparing gaskets and bolts, or confirming that a mating flange fits.

Formula

Dimensions are the JIS B 2220 values in mm
Bolt hole h = bolt diameter + 3 mm (+ 2 mm for M10)
Bolt spacing (arc) ≈ π × C / number of bolts
Thickness t of a raised face flange includes the raised face height f

Example

A 10K 100A flange has a 210 mm outside diameter, 18 mm thickness and a 175 mm bolt circle with eight M16 bolts in 19 mm holes, and fits a 114.3 mm outside diameter pipe. The bolt spacing is π × 175 / 8 ≈ 68.7 mm. The same 100A in 20K has a 225 mm outside diameter and a 185 mm bolt circle with eight M20 bolts (23 mm holes), so it does not bolt to 10K; 5K has a 200 mm outside diameter and a 165 mm bolt circle. None of them match the 190.5 mm bolt circle of ASME Class 150 NPS 4.

How to use

  1. Choose the nominal pressure (5K, 10K, 16K or 20K) and the nominal size in A.
  2. Read the outside diameter, thickness, bolt circle, number and thread size of the bolts, bolt hole diameter and matching pipe outside diameter.
  3. Compare with other sizes of the same nominal pressure in the table below, and check that the mating flange has the same nominal pressure and size.

Engineering notes

  • This chart covers JIS B 2220 steel pipe flanges in 5K, 10K, 16K and 20K: 10A–300A for 5K and 16K, and 10A–600A for 10K and 20K. 550A, and 5K and 16K above 300A, could be confirmed in only one published table and are left out. JIS B 2220 has no 175A or 225A for 16K and 20K.
  • Each value is used only where two published tables agree: ryutai.co.jp and sakutto-jis.com for 10A–300A, and ryutai.co.jp and hisaka.co.jp for 10K and 20K from 350A up. For 10K and 20K, the hisaka.co.jp table also agrees from 15A to 300A.
  • Thickness t of a raised face (RF) flange includes the raised face height f. For 10K and 20K, f is 1 mm for 10A–25A, 2 mm for 32A–250A and 3 mm from 300A up.
  • 16K and 20K have the same outside diameter, bolt circle, bolt count and size and hole diameter at every nominal size; only the thickness differs. 10K and 16K are the same up to 40A, but from 50A the bolt count is 4 against 8, so they do not mate.
  • Bolts of 20K flanges from 350A up are specified with a 3 mm fine pitch (M30×3, M36×3), which does not fit coarse threads (3.5 mm pitch for M30, 4 mm for M36). Check the pitch when ordering bolts and nuts.
  • The nominal pressure 10K comes from the old unit 10 kgf/cm² (about 0.98 MPa) and is a rating designation, not an allowable pressure. Allowable pressure depends on material and fluid temperature and follows the JIS B 2220 pressure–temperature ratings.
  • Korean KS flanges use the same 5K and 10K designations, but this chart is based on the JIS values, so check KS flanges against the KS tables. Bolt length, gaskets and hub and bore dimensions are not included.

Frequently asked questions FAQ

Does a JIS 10K flange mate with ASME Class 150?

Usually not. For example, 10K 100A has a 175 mm bolt circle with eight M16 bolts, while ASME Class 150 NPS 4 has a 190.5 mm bolt circle with eight 5/8 in bolts. The outside diameters and bolt circles differ, so check the mating flange's standard first.

Can a 10K flange be bolted to a 16K flange?

Up to 40A the outside diameter, bolt circle and bolt count and size are the same, so they bolt together; from 50A the bolt counts differ and they do not. Even when they bolt together, rate the joint at the lower of the two.

What does the K in 5K and 10K mean?

It is the nominal pressure, from the old unit kgf/cm². 10K is roughly the 10 kgf/cm² (0.98 MPa) class, but the actual allowable pressure depends on material and temperature, so check the pressure–temperature ratings.

How much larger is the bolt hole than the bolt?

In this chart, M10 bolts have 12 mm holes, 2 mm larger, and M12 and above have holes 3 mm larger than the bolt: 19 mm for M16, 23 mm for M20, 27 mm for M24 and 33 mm for M30.

KEEP WORKING

Compare outside diameter and bolt circle in the ASME flange chart to see whether an ASME flange mates, and find bolt pitch and stress area in the metric bolt and thread chart. Check the outside diameter and wall of the flanged pipe in the pipe schedule chart.