PIPING / H-Beam Size Chart

H-Beam Size Chart

Look up dimensions, area, unit mass (kg/m), moments of inertia and section moduli of KS D 3502 and JIS G 3192 H-beams, and total weight from length and quantity.

Inputs

Updates as you type

Results

Unit mass

94.028kg/m
Results
Cross-sectional area119.781 cm²
Root radius · r18 mm
Moment of inertia · Ix20,410.205 cm⁴
Moment of inertia · Iy6,754.83 cm⁴
Section modulus · Zx1,360.68 cm³
Section modulus · Zy450.322 cm³
Radius of gyration · ix13.054 cm
Radius of gyration · iy7.51 cm
Weight per piece564.17 kg
Total weight564.17 kg

KS D 3502 H-beam dimensions and properties

H × B × t1 × t2r · mmCross-sectional area · cm²Unit mass · kg/mIx · cm⁴Zx · cm³
100×100×6×81021.917.238377
125×125×6.5×91030.3123.8847136
150×75×5×7817.851466689
150×150×7×101140.1431.51,641219
200×100×5.5×81127.1621.31,844184
200×200×8×121363.5349.94,716472
250×125×6×91237.6629.64,052324
250×250×9×141692.1872.410,833867
300×150×6.5×91346.7836.77,209481
300×300×10×1518119.789420,4101,361
350×175×7×111463.1449.613,559775
350×350×12×1920173.87136.540,2952,303
400×200×8×131684.126623,7041,185
400×400×13×2122218.69171.766,6213,331
450×200×9×141896.767633,4511,487
500×200×10×1620114.2389.747,8461,914
600×200×11×1722134.41105.577,6322,588
700×300×13×2428235.49184.9201,4895,757
800×300×14×2628267.45209.9291,6577,291

Overview

Choose an H-beam size to see its cross-sectional area, unit mass (kg/m), moments of inertia, section moduli and radii of gyration. You can pick KS D 3502 (19 sizes on which two published tables agree) or JIS G 3192 (53 standard sections), and entering a length and quantity gives the weight per piece and in total. For the same nominal size, KS and current JIS can use different root radii r and so slightly different unit masses; the table under the results compares sizes within the chosen standard.

Formula

A = t1(H − 2t2) + 2Bt2 + (4 − π)r²
Unit mass [kg/m] = A [cm²] × 0.785 (density 7,850 kg/m³)
Ix = BH³/12 − (B − t1)(H − 2t2)³/12 + fillet terms
Iy = 2t2B³/12 + (H − 2t2)t1³/12 + fillet terms
Zx = Ix / (H/2),  Zy = Iy / (B/2)
ix = √(Ix/A),  iy = √(Iy/A)

Example

H 300×300×10×15 in KS D 3502 (r = 18) has an area of about 119.78 cm², a unit mass of about 94.03 kg/m, Ix of about 20,410 cm⁴ and Zx of about 1,361 cm³; a 6 m length weighs about 564.2 kg. The same size in JIS G 3192 (r = 13) has about 118.45 cm², 92.98 kg/m, Ix about 20,190 cm⁴ and Zx about 1,346 cm³, about 1% lighter, matching the published JIS values of 118.5 cm², 93.0 kg/m, 20,200 cm⁴ and 1,350 cm³ within rounding.

How to use

  1. Choose the standard (KS D 3502 or JIS G 3192) and the H × B × t1 × t2 size. KS offers only the 19 sizes on which two published tables agree.
  2. If you need total weight, enter the length and quantity. Leave them blank for section properties only.
  3. Read the unit mass, area, Ix and Iy, Zx and Zy and the radii of gyration, and compare with other sizes of the same standard in the table below.

Engineering notes

  • Area and section properties are calculated from the dimensions and root radius r. For the 53 JIS sizes they agree with published tables within 0.05% for area, 0.4% for unit mass and 0.5% for Ix, Iy, Zx and Zy (the tables round to three significant figures).
  • KS D 3502 tables use larger root radii than current JIS for many sizes: 300×300 is r = 18 (94.0 kg/m) in KS and r = 13 (93.0 kg/m) in JIS. Check the actual product's standard and the mill's table for ordering and structural checks.
  • KS includes only the 19 sizes on which two published tables (kspec.kr, excone.co.kr) agree on area and unit mass. Sizes where they differ, such as 900×300, or that appear in only one, such as 175×175, are left out.
  • Unit mass is nominal at 7,850 kg/m³. Actual weight can differ by the rolling tolerance, and bolt holes, splice plates and welds are not included.
  • Section properties are inputs to structural checks; they do not judge allowable load or deflection. Design members with the applicable code (KDS, AISC and so on) and structural calculations.
  • For sizes not listed or built-up H sections, enter H, B, t1, t2 and r in the steel weight calculator to get area and weight.

Frequently asked questions FAQ

For 300×300, is it 94 kg/m or 93 kg/m?

The standards use different root radii. KS D 3502 tables give r = 18 and 94.0 kg/m; current JIS G 3192 gives r = 13 and 93.0 kg/m. Check KS tables for products sold in Korea and JIS tables for Japanese-standard products.

Are H 300×150 and H 298×149 different products?

They belong to the same 300×150 series but are separate sections with different web and flange thicknesses. 298×149×5.5×8 is lighter than 300×150×6.5×9 (32.0 against 36.7 kg/m in JIS). Check the full H×B×t1×t2 on the drawing.

What are Ix and Zx used for?

Ix (moment of inertia) is used for beam deflection and Zx (section modulus) for bending stress, σ = M/Z. The strong-axis (x) values are much larger than the weak-axis (y) values, which is why H-beams are placed with the web vertical.

KEEP WORKING

Enter unlisted or built-up H sections directly in the steel weight calculator. Find splice bolts in the metric bolt and thread chart, and the outside diameter and wall of pipe resting on supports in the pipe schedule chart.