UNIT CONVERTER / Gas Flow Standard–Actual Converter

Gas Flow Standard–Actual Converter

Convert gas flow between standard conditions (Nm³/h, Sm³/h, scf) and actual operating pressure and temperature, with mass flow when the molar mass is given.

Inputs

Updates as you type

kPa

g/mol

Results

Actual (operating) flow

14.033m³/h
Results
Actual (operating) flow0.004 m³/s
Standard-condition flow100 m³/h
Actual/standard flow ratio0.14 ×
Absolute pressure801.325 kPa
Absolute pressure8.013 bar
Absolute temperature303.15 K
Reference condition0 °C · 101.325 kPa

Overview

Convert a standard-condition flow such as Nm³/h or Sm³/h, as stated on compressor and blower specifications or gas meters, into the volumetric flow at actual operating pressure and temperature, or the reverse. Gas volume changes strongly with pressure and temperature: the same amount of gas at 7 barg takes up roughly one eighth of its volume at atmospheric pressure. Pipe velocity and pressure drop need actual flow, while contracts, metering and performance comparisons use standard flow, so the two must be converted exactly. Enter the gas molar mass to get the mass flow as well.

Formula

Pabs = Pgauge + Patm
T [K] = T [°C] + 273.15
Qactual = Qstandard × (Pref / Pabs) × (T / Tref) × Z
Qstandard = Qactual × (Pabs / Pref) × (Tref / T) / Z
ρref = Pref × M / (R × Tref),  R = 8.314462618 J/(mol·K)
ṁ = Qstandard × ρref

Example

Converting 100 Nm³/h of compressed air (0 °C, 101.325 kPa basis) to 7 barg and 30 °C gives an absolute pressure of 801.325 kPa and 303.15 K, so the actual flow is about 14.03 m³/h, an actual/standard ratio of about 0.1403. With a molar mass of 28.96 g/mol (air), the density at 0 °C is about 1.292 kg/m³ and the mass flow about 129.2 kg/h. Conversely, an actual flow of 50 m³/h measured at 5 barg and 40 °C is about 273.0 Sm³/h on a 15 °C basis.

How to use

  1. Enter the flow and its unit, then choose the direction (standard → actual or actual → standard) and the reference condition (Nm³ at 0 °C, Sm³ at 15 °C and so on).
  2. Enter the operating pressure as gauge pressure with its unit, the operating temperature and the site atmospheric pressure. If needed, add the compressibility factor Z at operating conditions and the gas molar mass.
  3. Read the converted flow, the actual/standard ratio and the absolute pressure and temperature. Use the actual flow for pipe velocity; if you entered a molar mass, also read the mass flow.

Engineering notes

  • The ideal-gas law is corrected by the compressibility factor Z at operating conditions. Z at the reference condition is taken as 1; for gases whose Z departs noticeably from 1 at high pressure or low temperature, take Z from property data.
  • 'Standard conditions' differ by industry and contract: Nm³ usually means 0 °C, Sm³ 15 °C (ISO 13443) and US scf 60 °F. The US natural gas industry may use 14.73 psia, about 0.2% from this tool's 14.696 psia.
  • Enter operating pressure as gauge pressure and the site atmospheric pressure in its own field. The default 101.325 kPa is the sea-level standard atmosphere; use the actual atmospheric pressure at altitude.
  • Distinguish wet gas, which includes water vapor, from a dry-gas basis. This tool applies no moisture correction, so for compressed air or flue gas that needs one, follow the method of the applicable standard.
  • Mass flow uses the ideal-gas density at the reference condition. Example molar masses: air 28.96, nitrogen 28.01, oxygen 32.00, methane 16.04 g/mol; for mixtures use the composition-weighted mean.
  • Pipe velocity and pressure drop must use actual flow. Using standard flow in a high-pressure line overstates the velocity several times over.

Frequently asked questions FAQ

Are Nm³ and Sm³ the same unit?

Their reference temperatures differ. The same amount of gas that is 100 Nm³ on a 0 °C basis is about 105.5 Sm³ on a 15 °C basis. When comparing specifications and meter readings, check the reference temperature and pressure first.

When should I enter the compressibility factor Z?

When high pressure or low temperature takes the gas away from ideal behavior, enter Z at operating conditions. Z depends on composition and state and comes from property data or an equation of state; leaving it blank uses 1.

What if I only know the absolute pressure?

Enter the absolute pressure minus the atmospheric value as the gauge pressure. For example, 801.325 kPa absolute with 101.325 kPa atmospheric is 700 kPa (7 bar) gauge.

How do I enter scfm (ft³/min)?

This tool does not offer ft³ units, so multiply ft³/min by 0.0283168 to get m³/min, then choose the 'scf · 60 °F' reference condition.

Related guides

KEEP WORKING