Tank Sounding, Ullage and Reading Calibration Tables
Tank contents are managed by measuring a height and turning it into a volume. The height from the bottom to the liquid surface is the sounding; the empty height from a top reference down to the surface is the ullage. This guide shows how to convert one into the other, how to interpolate between rows of a calibration table, and how to get consumption and mass from changes in sounding, with examples.
Published:
Concepts
Sounding and ullage
Sounding is the height from the bottom datum to the liquid surface; ullage is the empty height from the top datum down to it. With the reference height Href between the two datums on the same vertical line, h = Href − u. The reference height may differ from the tank height, so check the datum of the calibration table or sounding pipe.
Height-volume relations depend on shape
In rectangular and vertical cylindrical tanks volume is proportional to height; in horizontal cylinders and tanks with sloped bottoms it is not. Simple shapes can be calculated, while irregular tanks use a calibration table listing volume against height.
Interpolating a calibration table
A calibration table gives volumes at regular heights. Values in between come from linear interpolation, V = V1 + (h − h1)(V2 − V1)/(h2 − h1). With close spacing the error is small, but it can grow near the bottom where the shape changes quickly.
Consumption and mass
The volume difference between two soundings is the consumption or receipt in between. Mass is volume times density at the liquid temperature; for liquids whose density changes with temperature, such as fuel oil, record the measurement temperature too.
Basic formulas
h = Href − u V = V(h) from geometry or a calibration table V = V1 + (h − h1)(V2 − V1)/(h2 − h1) Fill [%] = V / Vtotal × 100 ΔV = V(h2) − V(h1) m = V × ρ(T)
- h: sounding (liquid height), u: ullage (empty height), Href: reference height on the same vertical line, all in m.
- V(h): volume at height h in m³; h1, h2 and V1, V2: two adjacent rows of the calibration table.
- ρ(T): density at temperature T in kg/m³, m = V × ρ, ΔV = V(h2) − V(h1).
Worked example
Find the contents of a rectangular tank with internal dimensions 4 m × 3 m × 2 m, a 2 m reference height and 0.8 m ullage; then calculate the consumption and mass (diesel at 840 kg/m³) when the next day's sounding drops to 0.9 m. Finally check the interpolation error in a calibration table for a horizontal tank with a 2 m diameter and 5 m length.
Href = 2 m; u = 0.8 m → h = 1.2 m → V = 4 × 3 × 1.2 = 14.4 m³ Next day h = 0.9 m → V = 10.8 m³; ΔV = 3.6 m³ × 840 kg/m³ = 3024 kg Horizontal D 2 m × L 5 m: V(0.80) = 5.867 m³; V(0.90) = 6.856 m³ Interpolated V(0.85) = 6.362 m³; exact = 6.360 m³; Δ = 1.9 L
An ullage of 0.8 m is a sounding of 2 − 0.8 = 1.2 m, or 14.4 m³ of liquid. When the sounding drops to 0.9 m (10.8 m³), consumption is 3.6 m³, about 3,024 kg of diesel.
In the horizontal tank, 0.8 m holds 5.867 m³ and 0.9 m holds 6.856 m³. Interpolating 0.85 m linearly between them gives 6.362 m³, about 1.9 L above the exact 6.360 m³. For a table with 10 cm spacing, that is close enough for most tank management.
How to use this in practice
Turn daily soundings of ship fuel, fresh water and ballast tanks, or onshore storage tanks, into volumes and masses, and check consumption and receipts.
Build an approximate calibration table for a simple tank without one, or cross-check a calibration table against a calculation.
Common mistakes
- Entering ullage as a sounding: using the empty height as the liquid height turns the volume upside down.
- Assuming the reference height equals the tank height: the sounding pipe's datum may differ from the tank bottom or top.
- Using soundings taken with trim or heel without correction: ships need the trim correction tables as well.
Related calculators
Related guides
Frequently asked questions FAQ
If there is a calibration table, do I need the calculator?
A certified calibration table takes precedence. The calculator is for approximate figures on simple tanks without a table, or for checking that table values are in a sensible range.
What if different sounding pipes give different readings?
With trim or heel, the reading depends on where the sounding pipe is. Ships use calibration tables with trim and heel corrections; record the draft and trim at the time of measurement.
Which density should I use for mass?
Use the density at the liquid temperature when the sounding was taken. Fuel oil is often converted from a density at a reference temperature (for example 15 °C) with a temperature correction factor; follow that procedure.
References
Engineering Disclaimer
Calculations and examples are references based on general formulas and stated assumptions. Before design, construction, manufacturing, inspection or approval, check applicable standards, project requirements and approved manufacturer or vessel data, and follow the required review procedures. These results do not imply certification or design approval by any authority.